Low Voltage Cutoff Controller FORIOT DC 6-60V 30A Low Voltage Disconnect Protection Module with LCD Display Charging Discharging Controller Protection Switch Module

Free shipping on orders over $29.99

$12.74

$ 5 .99 $5.99

In Stock

About this item

  • Parameter Settings: Long press the "SET" to enter the parameter settings interface. Short press the "SET" to set the parameter with the "UP/DOWN". After setting completed, short press the "SET" to save
  • Charge Discharge Time Control: Start time control when setting OP parameter to non-zero. Start timing after the relay conducts, and the relay automatically disconnects at the end of timing to complete the charging and discharging process
  • LCD Screen: Low voltage protection module is equipped with a LCD high-definition display, which can display various parameters more clearly
  • Wide Applications: Low voltage controller is equipped with a 30A high-current relay, supports the control of DC 6-60V various batteries control
  • Attention: This product is a voltage controller that uses a relay to turn the output on and off. It only acts as a switch and cannot transform voltage



Product Description

Low Voltage Disconnect Protection Module

Charging mode IN

By setting the upper limit voltage "UP" and the lower limit voltage "dn"; when the battery voltage is less than or equal to the lower limit voltage "dn", the relay turns on and the charger starts charging the battery; when the battery voltage is more than or equal to the upper limit voltage "UP", the relay disconnects to complete an automatic charging; when the relay turns on, "IN" flickers, indicating that it is charging.

Charging Discharging Controller Protection
Charging Discharging Controller Protection

Discharge mode OUT

By setting the upper limit voltage "UP" and the lower limit voltage "dn"; when the battery voltage is greater than or equal to the upper limit voltage "UP", the relay turns on and starts discharging; when the battery voltage is less than or equal to the lower limit voltage "dn", the relay turns off and completes an automatic discharging function; when the relay turns on, the "OUT" flickers, indicating that it is discharging.

Functional description:

Button function

  • UP button: short press to switch the display % and time, long press for 5 seconds to switch the mode, charging mode: IN, discharge mode: OUT.
  • SET button: short press to view the currently set parameters; long press the SET button to enter the parameter setting interface, set UP: voltage upper limit, dn: voltage lower limit, OP: conduction time, dOP: delayed conduction time (0-999 seconds), FOP: forced conduction time (0-10 seconds) in discharge mode.
  • DOWN button: short press to turn off/on the relay enable (emergency stop function) after turning off, the LCD displays OFF and the relay is disconnected. Long press the DOWN button to set the LCD backlight status L-P: OFF backlight is always on, ON: the backlight automatically turns off after 5-10 minutes; after turning off, press any button to wake up.

Parameter Settings

  • A) Enter the parameter setting interface by pressing the SET key for a long time;
  • B) After entering the parameter setting interface, switch the setting parameters by pressing the SET key;
  • C) After choosing parameters, it can be set by UP/DOWN key to support short press and long press;
  • D) To set other parameters, repeat steps B and C;
  • E) After all parameters are set, press SET key for a long time, exit and save.

1. Charging/Discharging Time Control Function

When the time parameter OP is non-zero, start charging/discharging time control.

When the relay turns on a charge/discharge, the countdown begins; when the time is completed, the relay is automatically disconnected to complete a charge/discharge process; if the time is completed, in the charging mode, the detection voltage is less than the lower limit voltage dn or in the discharge mode, the detection voltage is more than the upper limit voltage UP, and the charging time control function is automatically turned off and flashes. Indicate H: ER reminds users that time parameter setting is unreasonable; press any key to stop flickering;

When the charging/discharging time control is not turned on, the product will record a complete time. When entering the time display interface, flashing shows the charging time, then exiting the time display interface or clearing the next time the charging is turned on (relay is turned on).

2. Automatic parameter detection:

When the parameters are set and exit, if the lower voltage limit DN is greater than the upper voltage up, the system will flicker to display "ERR" as a reminder.

3. Delayed turn-on function (0-999 seconds): completion of a charge/discharge, the interval between re-opening;

4. Discharge Conduction Forced Start Time (0-10S): After satisfying the relay conduction condition, the relay is forced to turn on (0-10S) to detect the battery voltage again. This function is mainly aimed at discharging function. Some test loads will pull down the lower limit voltage instantaneously at the moment of conduction, which will lead to the disconnection of the relay and the failure of normal discharge process.

Low Voltage Cutoff Controller

The Fat Rancher
Reviewed in the United States on January 4, 2025
Need to shed a load prior to maxing out a battery, the Foriot "Low Voltage Cutoff Controller FORIOT DC 6-60V 30A Low Voltage Disconnect Protection Module with LCD Display Charging Discharging Controller Protection Switch Module" fits the bill.No documentation, but should be easy enough to figure out. Arrives in a sealed antistatic bag.