Shopping Cart

Your cart is empty.

Your cart is empty.

110V 3CFM 1/4HP Single Stage Rotary Vane Air Vacuum Pump HVAC A/C Refrigeration Kit AC Manifold Gauge Set R134A R12 R22 R404A R410A with Carrying Bag/Tote

Free shipping on orders over $29.99

$108.99

$ 49 .99 $49.99

In Stock
  • This 3cfm 1 Stage 1/4hp Rotary Vane Vacuum Pump Manifold Gauge set Comes with 3 Hoses, the Hose connection :1/4"
  • 3 CFM 1/4 HP single-stage rotary vane vacuum pump
  • Diagnosis R134A R12 R22 R404A R410A
  • 3 color coded hose approximately 43 inches long: red/blue/yellow
  • Silicone inhibition index;



Product Description

manifold gauge set

High quality manifold with quick coupler:

Manifold Red Gauge (high): 0-800 PSI

Manifold Blue Gauge (low): 0-500 PSI

Gauge Reading for R12, R22, R134a, R410a

Red hose: 800psi-4000psi

Blue/Yellow hose: 600psi-3000psi

Hose length: 47 inch

Manifold fitting and hoses: 1/4"

Quick Connetors: 1/4”male SAE

Air Vacuum Pump

1/4 HP 3 CFM Air Vacuum Pump:

110V 60Hz 1/4 horsepower motor

3 CFM single-stage rotary vane vacuum pump

High efficiency and low noise, built-in large capacity cooling fan, long - term use

Storage bags to keep equipment clean and none dust

The drain plug is located at the bottom of the reservoir

Manifold gauge

Blue standard (low): diameter 2-1/2 ", 0-500 PSI

Red gauge (height): diameter 2-1/2", 0-800 psi

Includes 3-color coded 43-inch hose;(red hose 4000 psi / 800 psi;Blue/yellow hose 3000 psi / 600 psi)

Applicable to R134A, R12, R22, R22A, R404A, R410A, etc.

Air Vacuum Pump

Air Vacuum Pump Kit Including:

The package includes 1/4 HP 3 CFM air vacuum pump, AC manifold gauge set, 3 colored hoses, 1 bottle vacuum pump oil, 2 R410a adapters, toolkit bag, etc.

This kit are used for automotive air conditioning, HVAC work, refrigeration and industrial requirements that need high vacuum pull from a compact pump.

Precautions for vacuum pump maintenance

1. This product strictly prohibits the extraction of flammable, explosive, and toxic gases;

2. This product must not remove gases that are corrosive to metals and can react chemically with pump oil;

3. This product must not remove gases containing particulate dust and a large amount of water vapor;

4. The temperature of the extracted gas shall not exceed 40 ℃, and the operating environment temperature shall be between 5 ℃ and 60 ℃;

5. This product cannot be used as a compression pump or a delivery pump:

6. It is strictly prohibited to operate without oil;

7. When the pump is running, it is strictly prohibited to block the exhaust port;

8. - The voltage used for this product is 192-248V, 50HZ, and the socket must be grounded;

-When unplugging the power supply, be sure to hold the plug and not pull the power cord;

- Do not place heavy objects on the power cord, do not allow the power cord to be squeezed;

- Do not use damaged plugs and sockets;

- Do not use damp hands to plug or unplug the power plug;

- Do not plug or unplug the power plug or press the switch in areas with gas leaks.

9. Wear protective goggles when working with refrigerant;

10. Do not directly touch the refrigerant to prevent personal injury caused by the refrigerant;

11. When connecting to the power supply, it is required that all relevant equipment be properly grounded to prevent the risk of electric shock;

12. Due to the surface heating during pump operation, please do not touch the oil tank or motor casing during operation.

Precautions for customers before starting up

1. Upon receiving the new machine, check if there is any obvious damage to the machine and if there is any leakage from the matching oil bottle

2. Confirm that the machine is in good condition. You can unscrew the filter on the oil tank and directly fill it in. After all the oil bottles have been filled, the machine will stand still for a while and the oil mark line at the oil mirror position will be visible

3. Plug in the machine, turn on the switch, and the machine is running. At this time, you can unscrew the intake nozzle of the vacuum pump, block the intake nozzle with your hand, and feel if your fingers are being sucked. If so, it is judged that the vacuum pump is functioning properly and can be vacuumed normally

4. When the machine is running for a long time, do not open it and directly extract the atmosphere. Connect pipes or other equipment to operate and extract the vacuum. If the vacuum is extracted for a long time, it may cause the motor to burn out, so it is important to pay attention

Gauge Maintenance

Gauge

The refrigerant meter pointer does not point to 0

Solution: Remove the gauge cover, unscrew the plastic case, use a flat screwdriver to clamp it on the screw above the dial scale, turn it, and you can see that the dial pointer will move. Adjust it to position 0.

Vacuum pump often emits smoke and does not work

1. Be sure to add oil for use. The machine may produce a small amount of oil smoke during operation, which is a normal phenomenon. Add oil to the middle position of the oil mirror

2. If the pump is used for refueling but is in an open atmosphere, the oil fumes will increase. Only by connecting the equipment properly and not opening it for air extraction, there will be a small amount or even no oil smoke during the operation of the vacuum pump“

3. If the machine is not working, it is necessary to first determine whether the new machine is not working or if it has been used for a period of time. If the new machine is not working, it may be due to a collision during transportation that caused it to get stuck somewhere. You can try removing the fan cover, turning the fan blades clockwise, and then restarting after the rotation is smooth. If the machine does not work after running for a period of time, it may be due to poor gas extraction or improper use, resulting in the motor getting stuck. The above method can also be tried“


Brian Durand
Reviewed in Canada on February 21, 2025
Worked well for my mini split install. I did myself without any issues.
david bridges
Reviewed in Canada on January 14, 2025
Worked the way is should and came b4 I expected
Bluetooth Buyer
Reviewed in Canada on September 18, 2024
This thing sucks! But that’s a good thing. Vacuumed the lines of 2 mini split installs, seems to be good quality and does the job. Great for someone who want a to save some money on a DIY mini split install.
Cindy
Reviewed in the United States on August 26, 2024
This worked exactly as intended!
wayne callihoo
Reviewed in Canada on August 21, 2024
quick delivery, used once so far and worked good. Only issue I had is it didnt have fittings for 1234YF refrgerant had to buy seperate used to vacuum out a/c system for my truck when I had to replace the condensor and worked good.
Ali
Reviewed in the United States on July 14, 2024
The media could not be loaded.
Mike Skura
Reviewed in the United States on May 5, 2024
It worked fine for what I needed it for. Didn’t find any problems with it except for the gauges worked backwards.
Pat
Reviewed in the United States on January 6, 2024
I am very happy with the product
steve
Reviewed in the United States on January 31, 2024
Impressed with this vacuum pump! Powerful performance, reliable, and efficiently gets the job done. A huge help getting my mini split set up. A valuable addition to any DIY or professional setup.
Robert M.
Reviewed in the United States on April 14, 2024
System worked great as long as you don’t need to use refill cans. The threads on the hoses don’t match those on widely-available can taps.
Nasser
Reviewed in the United States on February 24, 2023
The first package ordered arrived soaked in oil. There was no way to clean ANYTHING! Sent the whole thing back (I am in Mexico) No questions asked by vendor or Amazon (like that!!). Waited a month, re-ordered the same thing. This time everything in perfect condition. When adding oil to the pump don't over torque the oil cap (it has an o-ring). There are 4 fittings in the package. Two of them can be connected to your Mini Split (Mine is a Carrier). Pump down was a breeze and the vacuum held just fine. Gauges functioned as expected. Also tested a bit of pressure (1 pound of refrigerant R410) and gauges worked as expected. The pump is NOT for big jobs, but it works on small mini splits (12000 BTU).
sergio villalobos
Reviewed in Mexico on October 16, 2023
Faltaba el tapon del deposito del aceite, tuve que improvisar con un tornillo
willy
Reviewed in the United States on August 5, 2022
I needed a set of gauges and vacuum pump for a one time setup. This worked great. For the one in a while home mechanic working on cars and ac units. This would be great. I know from years ago when I did it full time, I doubt this hold up to professional daily use but those are expensive oil filled sets