1.Model:100a


About this item

  • Application: photovoltaic wind energy new energy, battery circuits, car charging piles, energy storage distribution cabinets, etc.
  • Features: high current, high-efficiency arc extinguishing mechanism, fast closing and opening mechanism
  • Use: for circuit protection, with short circuit protection, overload protection, can also be used as a normal switch, can be hot switched, can be reused and protecte
  • Installation & Wiring: standard 35mm rail mounting, maximum 35mm2 wiring capacity, maximum screw torque 3.5Nm, can be removed and secondary installation



Product Description

DZ47Z-125H DC260-500V Banner
Rated voltage DC260-500V
Rated current 100A, 125A, 150A
Functions Overload protection, short-circuit protection, isolation switch
Breaking capacity 8kA
Impulse voltage 8kV
Tripping Curve Type C
Polarized Non-polarized 2 poles
Trip type Thermal-magnetic
Mechanical durability 7000
Electrical durability 3500
Mounting 35MM standard DIN rail
Crimping Screw crimp
Maximum wiring capacity 35mm2/2awg
Maximum ultimate torque 3.5Nm
Accessories(optional install) OF (auxiliary), MX (shunt trip release), SD (alarm), MV (overvoltage), MN (undervoltage), MX+OF (shunt trip release + auxiliary), MV+MN (overvoltage and undervoltage)
Applications Solar DC PV system, wind power system, battery-inverter system, battery charging system, car charging system etc

Silver alloy contact

Circuit breakers generate high-temperature arcs during protection and manual operation. The use of silver material can effectively prevent the melting of contact points caused by high-temperature arcs, thereby extending the service life of the circuit breaker and improving its breaking capacity.

100-250V-curve

Type C trip curve

t(s): time

I/In: current multiplier

When the actual line current current exceeds the rated current of the circuit breaker, the circuit breaker starts to activate the thermal overload protection, but it is not immediately de-coupled, but proceeds slowly, and the de-coupling time decreases with the increase of the current, and the circuit breaker is immediately trip when the circuit current exceeds 5-10 times of the rated current of the circuit breaker. When the circuit is short-circuited, the current current usually exceeds 10 times the calibrated current, and the circuit breaker is immediately trip.

Non-polarized

Support current double flows

Customer Reviews
4.0 out of 5 stars 3
Voltage DC100-250V DC260-500V DC510-1000V
Current 100A, 125A, 150A 100A, 125A, 150A 100A, 125A, 150A